RoHS COMPLIANCE
itg produces „lead-free“ oxygen cells as drop-in replacements and can look back on years of intensive field tests … MORE
|
|
I-20 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
0 - 2,500 ppm NO |
Special Features: |
fast response time, very low cross interference to H2S |
|
Zoom | 360° |
SPECIFICATION
MSDS
|
|
I-21 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
0 - 2,500 ppm NO |
Special Features: |
integrated potentiostat |
|
Zoom |
SPECIFICATION
MSDS
|
|
I-25 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
0 to 500 ppm |
Special Features: |
highly sensitive, fast response time |
|
Zoom | 360° |
SPECIFICATION
MSDS
|
|
I-27 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
1 - 500 ppm NO |
Special Features: |
for dry gas environments |
|
Zoom |
SPECIFICATION
MSDS
|
|
I-30 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
0 - 2,000 ppm CO |
Special Features: |
low baseline |
|
Zoom | 360° |
SPECIFICATION
MSDS
|
|
I-31 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
0 - 2,000 ppm CO |
Special Features: |
integrated potentiostat |
|
Zoom |
SPECIFICATION
MSDS
|
|
I-41 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
50 - 1000 ppm H2S |
Special Features: |
continuous use, no H2 cross sensitivity |
|
Zoom |
SPECIFICATION
MSDS
|
|
I-42 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
500 - 10000 ppm H2S |
Special Features: |
continuous use, no H2 cross sensitivity |
|
Zoom |
SPECIFICATION
MSDS
|
|
I-43 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
500 - 10000 ppm H2S |
Special Features: |
continuous use, no H2 cross sensitivity |
|
Zoom | 360° |
SPECIFICATION
MSDS
|
|
I-44 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
1 - 50 ppm H2S |
Special Features: |
continuous use, no H2 cross sensitivity |
|
Zoom | 360° |
SPECIFICATION
MSDS
|
|
I-46 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
1 - 50 ppm H2S |
Special Features: |
continuous use, no H2 cross sensitivity |
|
Zoom |
SPECIFICATION
MSDS
|
|
I-50 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
0 - 500 ppm NO2 |
Special Features: |
fast response time |
|
Zoom | 360° |
SPECIFICATION
MSDS
|
|
I-51 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
0 - 500 ppm NO2 |
Special Features: |
integrated potentiostat |
|
Zoom |
SPECIFICATION
MSDS
|
|
I-60 |
Principle: |
Amperometric Fuel Cell |
Measurement Range: |
0 - 500 ppm SO2 |
Special Features: |
specially designed for stack-gas measurement |
|
Zoom |
SPECIFICATION
MSDS
|
|
ILF-11 |
Principle: |
Galvanic Fuel Cell |
Measurement Range: |
0 - 35 Vol. %O2 |
Special Features: |
Lead free, RoHS compliant, long-life expectancy |
|
Zoom |
SPECIFICATION
MSDS
|
|